Process validation and preclinical development of a new PET cerebral blood flow tracer [11C]MMP for initial clinical trials

Abstract

Background

2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) is commonly used for diagnosis of dementia because brain glucose metabolism reflects neuronal activity. However, as [18F]FDG is an analogue of glucose, accumulation of tracer in the brain is affected by plasma glucose levels. In contrast, cerebral blood flow (CBF) tracers are theoretically unaffected by plasma glucose levels and are therefore expected to be useful alternatives for the diagnosis of dementia in patients with diabetes. The techniques currently used for CBF imaging using single photon emission computed tomography (SPECT) and [15O]H2O positron emission tomography (PET), but these are limited by their insufficient resolution and sensitivity for regional brain imaging, especially in patients with brain atrophy. N-isopropyl-4-[11C]methylamphetamine ([11C]MMP) is a possible CBF tracer with high resolution and sensitivity that exhibits comparable performance to that of [15O]H2O in conscious monkey brains. We performed process validation of the radiosynthesis and preclinical development of [11C]MMP prior to clinical translation.

Results

The decay-corrected yields of [11C]MMP at the end of synthesis were 41.4 ± 6.5%, with 99.7 ± 0.3% radiochemical purity, and 192.3 ± 22.5 MBq/nmol molar activity. All process validation batches complied with the product specifications. The acute toxicity of MMP was evaluated at a dose of 3.55 mg/kg body weight, which is 10,000 times the potential maximum clinical dose of [11C]MMP. The acute toxicity of [11C]MMP injection at 150 or 200 times, to administer a postulated dose of 740 MBq of [11C]MMP, was also evaluated after the decay-out of 11C. No acute toxicity of MMP and [11C]MMP injection was found. No mutagenic activity was observed for MMP. The effective dose calculated according to the Medical Internal Radiation Dose (MIRD) method was 5.4 µSv/MBq, and the maximum absorbed dose to the bladder wall was 57.6 µGy/MBq. MMP, a derivative of phenylalkylamine, showed binding to the sigma receptor, but had approximately 1/100 of the affinity of existing sigma receptor imaging agents. The affinity for other brain neuroreceptors was low.

Conclusions

[11C]MMP shows acceptable pharmacological safety at the dose required for adequate PET imaging. The potential risk associated with [11C]MMP PET imaging is well within the acceptable dose limit.

Background

Most of the energy for brain activity is supported by the oxidative metabolism of glucose, but as the storage of oxidative substrates in brain tissue is extremely low, the brain requires a continuous supply of glucose and oxygen from the bloodstream. Therefore, in healthy brain tissues, neuronal activity, glucose consumption, and blood flow are well correlated. This is the basis for using 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG), a sugar analogue, to study neuronal function in health and disease (Ishii 2002; Shimada et al. 2017). One of the most common applications of [18F]FDG in brain imaging is in the diagnosis of dementia, especially Alzheimer’s disease (AD) (Minoshima 2003). As [18F]FDG positron emission tomography (PET) enables clear anatomical and functional localization in the brain, considerable diagnostic information can be obtained for dementia (Minoshima et al. 1994, 2022). For example, AD is characterized by a prominent decrease in [18F]FDG uptake in the posterior cingulate, precuneus, and/or temporoparietal lobe, which is termed AD pattern. In contrast, in frontotemporal dementia, as the name suggests, decreased [18F]FDG uptake is observed in the frontal lobe and inferior temporal surface, whereas in dementia with Lewy bodies, the characteristic finding is decreased [18F]FDG uptake in the occipital lobe (Minoshima et al. 2022).

Although [18F]FDG is a standard tracer used for the clinical diagnosis of dementia, its diagnostic accuracy has been reported to be hampered in subjects with poorly controlled glycemia, for example in those with diabetes mellitus (DM) (Burns et al. 2013; Ishibashi et al. 2015). The findings of these previous studies imply that an individual with elevated plasma glucose levels can be mistakenly diagnosed with AD when [18F]FDG is used. Theoretically, [18F]FDG competes with glucose in glucose transporters and hexokinases (Wienhard 2002) and therefore affects the uptake of [18F]FDG in the brain.

As the prevalences of both dementia and DM inevitably increase with age (Cowie et al. 2010; Wada-Isoe et al. 2012), there is a rapid increase in patients with both DM and dementia in an ageing society. Therefore, an alternative to [18F]FDG is needed for the diagnosis of dementia in patients with DM. The most promising option is measurement of regional cerebral blood flow (CBF) (Matsuda et al. 2007; Tang et al. 2004) because neuronal activity is closely coupled to regional changes in CBF (Attwell and Iadecola 2002; Villringer and Dirnagl 1995). However, current modalities such as single photon emission computed tomography (SPECT) and [15O]H2O PET have limitations for the early diagnosis of dementia due to their low image resolution. As ageing causes atrophy evident as enlargement of the ventricles and dilation of the cerebral sulcus, low-resolution images can underestimate accumulation. To address this situation, we developed N-isopropyl-p-[11C]methylamphetamine ([11C]MMP) (Toyohara et al. 2020a) as a carbon-11 alternative to the standard SPECT CBF tracer N-isopropyl-p-[123I]iodoamphetamine (Ishii et al. 2009). [11C]MMP was highly incorporated and widely distributed in grey matter regions in the brains of conscious monkeys. The local distribution pattern of [11C]MMP closely resembled that of [15O]H2O, and the standardised uptake value (SUV) of the early phase scan showed a good correlation with the regional CBF calculated by [15O]H2O PET. These promising data prompted us to develop [11C]MMP as a novel CBF tracer for the diagnosis of dementia in patients with DM. Before entering the initial clinical trials, it is mandatory to perform a process validation of [11C]MMP production for clinical use and evaluate the preclinical toxicity and radiation dosimetry estimate from mouse biodistribution data.

Methods

General

The MMP was custom synthesized by the Nard Institute (Kobe, Japan) using methods described previously (Toyohara et al. 2020a). All other chemical reagents were obtained from commercial sources. Male ddY mice were obtained from Japan SLC (Hamamatsu, Japan). Sprague–Dawley rats [Crl: CD(SD)] were obtained from Jackson Laboratory Japan (Yokohama, Japan). Animal studies were approved by the Animal Care and Use Committee of the Tokyo Metropolitan Institute for Geriatrics and Gerontology (Approval Nos. 22,015 and 23,007) and Nihon Bioresearch (Hashima, Japan; Approval Nos. 430,085 and 430,086). Acute toxicity studies were performed under the “Revisions of the Guidelines for Single and Repeated Dose Toxicity Studies” (PMDA, 1993). Ames test was performed under the “Guidance on Genotoxicity Testing and Data Interpretation for Pharmaceuticals Intended for Human Use” (PMDA, 2012).

N-isopropyl-1-(4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)phenyl)propan-2-amine

The pinacol boronic ester (Bpin) precursor, N-isopropyl-1-(4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)phenyl)propan-2-amine, was purchased from Aquila Pharmatech (Waterville, OH). Characterization of the Bpin precursor was performed by 1H nuclear magnetic resonance (NMR) and high-resolution electrospray ionization-mass spectrometry (HR-ESI-MS) analysis. 1H-NMR spectra were recorded in CDCl3 as a solution using tetramethylsilane as the internal standard on a JEOL 400 MHz spectrometer (Akishima, Japan). Multiplicities are indicated as s (singlet), d (doublet), or m (multiplet). HR-ESI-MS spectra were recorded on a Q Exactive equipped with an Ultimate 3000 high-performance liquid chromatography (HPLC) system (Thermo Fisher Scientific, Waltham, MA). 1H NMR (CDCl3, 400 MHz): δ 7.73 (d, J = 8.0 Hz, 2 H), 7.17 (d, J = 4.0 Hz, 2 H), 3.03 (m, 1H), 2.93 (m, 1H), 2.78 (m, 1H), 2.58 (m, 1H), 1.34 (s, 12 H), 1.01 (m, 9 H). HRMS (ESI) m/z calculated for C18H30BNO2 [M + H]+ 304.2554 found 304.2442. Chemical purity of the Bpin precursor was determined by HPLC analysis. For analysis, an analytical column [Inertsil ODS-3 5-µ, 4.6-mm inner diameter (id) × 250-mm length] purchased from GL Science (Kyoto, Japan) was used and an isocratic elution was applied using CH3CN/H2O/trifluoroacetic acid (45/55/0.1, v/v/v) at a flow rate of 1 mL/min [ultraviolet (UV) detector at 245 nm]. Retention time (rt) of the Bpin precursor was 5.0 min (purity, 94.7%).

Automated radiosynthesis

[11C]MMP was synthesized by methylation of the Bpin precursor with [11C]CH3I in a palladium-promoted Suzuki cross-coupling reaction (Fig. 1) (Doi et al. 2009). The [11C]MMP labeling conditions were the same as those optimized for labeling phenylboronate reported previously (Table 1, entry 4 and scheme 3; Doi et al. 2009). The HPLC analytical yield of [11C]MMP under these conditions was greater than 90% (Additional file1: Fig. S2), and the reaction was nearly quantitative. Therefore, no further optimization of the conditions was performed.

Fig. 1
figure 1

Radiosynthesis of [11C]MMP

Table 1 Product release specification and validation test results of [11C]MMP

[11C]CO2 was produced by proton irradiation of a gas mixture of 99.5% nitrogen/0.5% oxygen (Taiyo Nippon Sanso JFP, Kawasaki, Japan) at 50 µA for 30 min using an HM-20 cyclotron (Sumitomo Heavy Industries, Tokyo, Japan). [11C]CH3I was produced from [11C]CO2 with a CFN-MPS100 multipurpose synthesiser (Sumitomo Heavy Industries). A flow chart of the synthesizer is shown in Additional file 1: Fig. S1. A solution of tri(o-tolyl)phosphine (3.9 mg, 12.8 µmol) in N,N-dimethylformamide (DMF) (0.15 mL) and the Bpin precursor (2.4 mg, 8 µmol) in DMF (0.1 mL) was prepared. Immediately before the end of irradiation, this solution was added to a dry septum-equipped vial (Additional file 1: RV2 in Fig. S1) containing a mixture of K2CO3 (1 mg, 7.2 µmol) and tris(dibenzylideneacetone)dipalladium(0) (2.9 mg, 3.2 µmol). The [11C]CH3I produced was trapped in the reaction mixture of DMF (0.25 mL) with air cooling. The reaction mixture was heated to 60 °C for 5 min. After adding 1.5 mL of a dilute solution (CH3CN/25 mM CH3COOH/25mM CH3COONH4 = 15/42.5/42.5, v/v/v), the reaction mixture was passed through Fine Filter F (Forte Grow Medical, Sano, Japan) equipped with glass fiber wool, followed by injection onto the preparative HPLC: YMC-Pack Pro C18 RS S-5 μm [10-mm id × 250-mm length, YMC, Kyoto, Japan] with a mobile phase of CH3CN/50 mM CH3COOH/50mM CH3COONH4 (30/35/35, v/v/v) at a flow rate of 4.5 mL/min (UV detector at 228 nm). The rt of [11C]MMP was 6.5 min (Additional file 1: Fig. S2). The fraction of [11C]MMP was collected in a flask containing 0.2 mL of 250 mg/mL ascorbate injection (Nichi-Iko Pharmaceutical, Toyama, Japan) and 0.2 mL of 10% polyoxyethylene (20) sorbitan monooleate (polysorbate 80) (MP Biomedicals, Santa Ana, CA) in ethanol (Imazu Chemical, Tokyo, Japan) and evaporated to dryness. The residue was dissolved in 20 mL of physiological saline containing 0.125% (v/v) polysorbate 80, and the solution was filtered through a 0.22-µm membrane filter (Millex GV, Merck Millipore, Billerica, MA).

Quality control

Filter integrity was assessed using a bubble point tester (SLTEST000; Merck Millipore). The pH value of the injection solution was determined using a pH meter (LAQUA F-72; Horiba, Kyoto, Japan). Residual solvents in the injection solution were measured by capillary gas chromatography using a GC-2014 or GC-2030 system with LabSolutions software (Shimadzu, Kyoto, Japan). Radionuclide was identified by determining half-life measurement using a Capintec CRC-55tR dose calibrator (Florham Park, NJ) and photopeak measurement at 511 keV using a NaI(Tl) radiation detector (US-2000, Universal Giken, Odawara, Japan). The limulus amoebocyte lysate (LAL) test was performed on a Toxinometer ET-6000 (Fujifilm Wako Pure Chemical, Osaka, Japan). Finally, a sample of the product formulation was tested for sterility post-release using direct inoculation in accordance with the Japanese Pharmacopeia, 18th edition (PMDA, 2021).

HPLC analysis was performed on a Shimadzu Prominence HPLC system equipped with a model LC-20AD pump, a model SPD-20A UV absorbance detector (set at 220 nm), a GABI 3 × 3-inch NaI scintillation detector (Elysia-Raytest, Straubenhardt, Germany), and an analytical column (Titan C18 1.9-µm, 2.1-mm id × 50-mm length) purchased from Sigma-Aldrich (St. Louis, MO). Operation of the Shimadzu Prominence HPLC system was controlled using Shimadzu LabSolutions software. For analysis, an isocratic elution was applied using CH3CN/50 mM CH3COOH/50mM CH3COONH4 (20/40/40, v/v/v) at a flow rate of 0.25 mL/min. The rt of the authentic standard MMP was 6.2 min (Additional file 1: Fig. S3).

The residual amounts of Pd in the final product were analysed with an inductivity coupled plasma mass spectrometer (ICP-MS) (Agilent 7700x; Agilent, Santa Clara, CA). The detection limit is approximately 100 ng/mL. ICP-MS analysis was performed at the Shimadzu Techno-Research (Kyoto, Japan).

Toxicity study

In Japan, the structure of nonclinical toxicology studies for PET drugs in clinical research is the responsibility of the ethics committee of each institution or the subcommittee of specialities of PET drugs. According to the method used previously for approval of PET drugs for clinical use in our institute (Toyohara et al. 2013, 2016, 2020b; Sakata et al. 2017), we performed single-arm acute toxicology studies of the active pharmaceutical ingredient (MMP) and final dose formulation ([11C]MMP injection). Mutagenicity tests will also be conducted, as there are concerns about stochastic effects on genotoxicity.

Acute toxicity studies were performed at the Hashima Research Center, Nihon Bioresearch, under non-Good Laboratory Practice (GLP) control. Acute toxicity of MMP was tested in Sprague–Dawley rats. MMP at a dose of 3.55 mg/kg body weight (0.71 mg/mL in 10 v/v% dimethyl sulfoxide containing water for injection) was injected intraperitoneally into 5-week-old rats weighing 143–172 g (male, n = 5) and 129–135 g (female, n = 5). The dose of 3.55 mg/kg body weight is the 10,000-fold equivalent of the postulated maximum administration dose (1.85 nmol/0.355 µg/kg body weight) of 740 MBq [11C]MMP, with the lowest molar activity (Am) of 10 MBq/nmol for humans weighing 40 kg. Rats were observed frequently until 1 h and then at 2, 4, and 6 h after the injection on day 1, and thereafter once daily for 14 days for clinical signs of toxicity. Rats were weighed on days 1, 2, 4, 7, 10, and 14. At the end of the 14-day observation period, the rats were euthanized by exsanguination under isoflurane anaesthesia, and a macroscopic analysis of the autopsy samples was performed.

Three batches of [11C]MMP were prepared and tested after the decay-out of 11C. Solutions with decayed [11C]MMP were individually injected intravenously into 5-week-old male (162–174 g) and female (132–149 g) rats (n = 3 each) at doses of 4.05 µg/8.2 mL/kg body weight, 4.46 µg/7.5 mL/kg body weight and 5.86 µg/8.2 mL/kg body weight, for each of the three batches, equivalent to 150 and 200 times the postulated administration dose of 740 MBq [11C]MMP for humans. After injection of [11C]MMP, the rats were observed for clinical signs of toxicity for 14 days, and a macroscopic analysis was then performed as described above.

Mutagenicity tests were performed at the Hashima Research Center, Nihon Bioresearch, under non-GLP control. MMP was tested for mutagenicity by the Ames test with four histidine-requiring strains of Salmonella typhimurium (TA98, TA100, TA1535, and TA1537) and one strain of Escherichia coli (WP2uvrA), with and without the S9 mixture, at a dose range of 78.1–5000 µg/plate according to the standard method.

Dosimetry

[11C]MMP (8.1 MBq/17 pmol) was injected intravenously into 8-week-old male ddY mice (37.8–42.4 g). The tracer-injected mice were housed individually in filter-paper-lined animal-rearing cages until the time of euthanasia. Mice were euthanized by cervical dislocation at 1, 5, 15, 30, 60, and 90 min after injection (n = 4 each). Blood was collected by heart puncture, and the tissues were harvested. Radioactivity excreted into urine was recovered from the cage floor and by cystocentesis from the urinary bladder. The samples were measured for 11C radioactivity with an auto-gamma counter (Hidex-AMG, Turku, Finland) and weighed. Tissue uptake of 11C was expressed as the percentage of injected dose per organ (%ID/organ) or the percentage of injected dose per gram of tissue (%ID/g). The tissue distribution data were extrapolated to an adult male phantom using the %kg/g method (Blau 1975). The radiation absorbed dose and effective dose for human adults were estimated using OLINDA/EXM software (Vanderbilt University, Nashville, TN) (Stabin et al. 2005). Effective dose was estimated using the risk-weighting factor of ICRP Publication 103 (ICRP 2007).

Receptor selectivity

Interaction of MMP with 28 binding sites was examined, including major classes of neurotransmitter receptor, uptake system, and ion channels (Sekisui Medical, Naka, Japan). MMP was tested in all assays at 10 µM. Regarding the sigma receptor, a competitive inhibition curve was created for MMP and a positive control, haloperidol, and the concentration that inhibited binding by 50% (IC50 value) was calculated using GraphPad Prism ver. 10.2.3 (GraphPad Software, San Diego, CA). Each determination was made in duplicate.

Results

Automated radiosynthesis

The three batch production runs had activity yields of 6177 ± 1086 MBq, decay-corrected yields of 41.4 ± 6.5%, radiochemical purity of 99.7 ± 0.3%, and Am of 192.3 ± 22.5 MBq/nmol at the end of synthesis (Table 1). The average synthesis time following target bombardment was 32 min. All batches of [11C]MMP injection met the quality control (QC) criteria listed in Table 1. [11C]MMP was stable up to 90 min after end of synthesis, with acceptable appearance, pH of 5.36 ± 0.12, and radiochemical purity of 99.7 ± 0.2% (Table 2).

Table 2 Product specification and stability test results of [11C]MMP

Toxicity study

Acute toxicity in rats was evaluated after single intraperitoneal injection of MMP at a dose of 3.55 mg/kg and a single intravenous injection of one of the three batches of [11C]MMP preparation at a dose range of 4.05–5.86 µg/kg. There was no mortality in the rats during the 14-day observation period. All rat groups showed normal gains in body weight, and no clinical signs of toxicity were observed over the 15-day period. The post-mortem macroscopic examination found no abnormalities.

A reverse bacterial mutation test performed using Salmonella thyphimurium and Escherichia coli detected no mutagenic activity for MMP.

Dosimetry

Tissue distributions of radioactivity after injection of [11C]MMP into mice are shown in Fig. 2, and the data are listed in Tables 3 and 4.

Fig. 2
figure 2

Regional decay-corrected time activity curves. High radioactivity concentration (a) and accumulation (b) are observed after intravenous injection of [11C]MMP into mice. Data are presented as the mean ± standard deviation (n = 4)

Table 3 Tissue distribution of radioactivity in mice after intravenous injection of [11C]MMP
Table 4 Organ distribution of radioactivity in mice after intravenous injection of [11C]MMP

Radioactivity concentrations in the blood decreased rapidly after [11C]MMP injection. The lung showed the highest initial radioactivity concentration (28%ID/g) and then rapidly decreased. The kidney showed the highest initial radioactivity (7.4%ID/organ) and peaked (9.5%ID/organ) at 5 min after injection and then slowly decreased. Excretion of radioactivity into the bladder and urine increased gradually in response to the clearance of radioactivity from the kidney, reaching 58%ID/organ (bladder + urine) at 90 min after injection. Radioactivity of the liver peaked (15%ID/organ) at 15 min after injection, before clearing. Radioactivity levels of the small intestine and large intestine (6.8%ID/organ and 2.7%ID/organ, respectively) peaked at 5 min, and showed clearance of radioactivity. These data suggest that radioactivity was excreted mainly by the urinary system.

The radiation absorbed dose was estimated from these biodistribution data (Table 5). The absorbed dose (µGy/MBq) was highest in the urinary bladder wall (57.6), kidney (8.6), lung (7.3), and pancreas (5.5). The effective dose according to the risk-weighting factors of ICRP publication 103 (ICRP 2007) was estimated as 5.36 µSv/MBq.

Table 5 Absorbed dose of [11C]MMP for human adults estimated from mouse data

Receptor selectivity

MMP (10 µM) showed binding to the sigma receptor (inhibition 86%), but had approximately less than 1/100 of the affinity (IC50 = 1.1 µM) of the existing sigma receptor ligand, haloperidol (IC50 = 1.6 nM) (Additional file 1: Fig. S4). The affinity for other brain neuroreceptors was less activity (inhibition < 50%) (Additional file 1: Table S1).

Discussion

We performed three process validation runs of [11C]MMP. The obtained activity yields (4960–7050 MBq) and high Am (169.7–222.9 MBq/nmol) were adequate for clinical research purposes. The three validation runs of [11C]MMP met the QC release criteria. Contamination of Pd in the final product was below the limit of detection (< 100 ng/mL). No degradation of [11C]MMP in formulation was confirmed up to 90 min. Taken together, the radiolabeling process of [11C]MMP on a CFN-MPS100 was of sufficient quality for clinical use.

In a previous study, [11C]MMP was synthesized by methylation of the corresponding tributyltin precursor with [11C]CH3I in a palladium-promoted Stille cross-coupling reactions. Although we have used Stille coupling for production of PET tracers for clinical use in our facility (Toyohara et al. 2009, 2011), anxiety exists regarding the contamination of toxic tin-containing by-products, which are difficult to remove perfectly from the reaction mixture. Palladium-mediated cross-coupling of boronic acid or boronic esters with electrophiles, termed Suzuki coupling, is an alternative to Stille coupling. In this study, we implemented a Bpin precursor and found that Suzuki coupling was more effective than Stille coupling using the corresponding tributyltin precursor. The isolated yield was significantly improved, by a factor of 3 to 4, compared to Stille coupling. Furthermore, the methylation reaction condition was milder in Suzuki coupling (60 °C for 5 min) than in Stille coupling (100 °C for 5 min). Another advantage of Suzuki coupling is that it does not use copper catalysts. A very small amount of copper (120 and 260 ng/mL) was detected in two samples of previous products (Toyohara et al. 2020a). Although this amount of Cu content in the final product was much lower than the limit set (34 µg/mL) as the permitted daily exposure in the “Guideline for Elemental Impurities [ICH-Q3D (R2)]” (PMDA, 2023), periodic analysis will be required to ensure the quality of the product.

The absence of any abnormality in rats in the acute toxicity test, together with the absence of mutagenicity of MMP, demonstrated the clinical suitability of [11C]MMP for first clinical trials in healthy volunteers. Taking into account the allometric scaling factor (Reagan-Shaw et al. 2008), the Non-Observed Adverse Effect Level (NOAEL) of MMP is estimated as > 3.0 µmol/0.58 mg/kg, which is 1,600 times the postulated maximum administration dose when 740 MBq of [11C]MMP with a low Am (10 MBq/nmol) is injected into a human subject of body weight 40 kg. Acute single intravenous administration toxicity test using decay-outed [11C]MMP final product, which includes all administered components, most reflects the clinical administration status. When considering the allometric scaling factor, NOAEL is estimated as at least 24.3 times the postulated maximum dose (740 MBq) of the tracer. As the calculated contents of MMP at the end of synthesis in three batch productions are ≤ 1.5 µg/740 MBq (0.7 ± 0.1 µg/740 MBq), the potential risk associated with [11C]MMP injection is considered to be within the toxicologically acceptable range (Koziorowski et al. 2017).

Radiation absorbed dose was highest in the urinary bladder wall, followed by kidney, lung, and pancreas. The effective dose was well within the previously reported range (3.2–14.1 µSv/MBq) for 11C-labelled PET tracers (Zanotti-Fregonara et al. 2021). In the case of administration of 740 MBq of [11C]MMP, effective dose was estimated as 4.0 mSv, which is within the strict limit of 10 mSv set by the ICRP recommendation (ICRP 1991) and practised in Europe. In this condition, the highest absorbed dose in the urinary bladder wall was estimated as 42.6 mGy, which is also within the strict limits for individual organs (30 mSv for sensitive organs and 50 mSv for all others), as required by the US Radioactive Drug Research Committee regulations (FDA, 2010).

MMP showed binding to the sigma receptor (IC50 = 1.1 µM). Since the estimated density of the sigma receptor in the human brain is approximately 3–60 nM, radioligands with nanomolar affinity (< 10 nM) are theoretically needed for imaging of the sigma receptor (Toyohara et al. 2021). Therefore, contribution of sigma receptors to the distribution of [11C]MMP in the brain is thought to be negligible.

Conclusions

Automated synthesis of [11C]MMP for clinical use was achieved successfully and efficiently. All three batches of process validation complied with the product specifications. Preclinical toxicology studies indicated that [11C]MMP shows acceptable pharmacological safety at the dose required for adequate PET measurements. A single intravenous injection of 740 MBq of [11C]MMP leads to an estimated effective dose of 4.0 mSv and a highest absorbed dose to an organ of 42.6 mGy. The potential risk associated with [11C]MMP PET measurements is well within acceptable dose limits.

Data availability

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Abbreviations

AD:

Alzheimer’s disease

Am:

Molar activity

Bpin:

Pinacol boronic ester

CBF:

Cerebral blood flow

DM:

Diabetes mellitus

DMF:

N, N-dimethylformamide

FDA:

US Food and Drug Administration

FDG:

2-deoxy-2-fluoro-D-glucose

GLP:

Good laboratory practice

HPLC:

High-performance liquid chromatography

HR-ESI-MS:

High-resolution electrospray ionization-mass spectrometry

ICH:

International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use

ICRP:

International Commission on Radiological Protection

ID:

Inner diameter

IMP:

N-isopropyl-p-iodoamphetamine

LAL:

Limulus amoebocyte lysate

MIRD:

Medical internal radiation dose

NMR:

Nuclear magnetic resonance

NOAEL:

Non-observed adverse effect level

MMP:

N-isopropyl-p-methylamphetamine

%ID:

Percentage of injected dose

PET:

Positron emission tomography

PMDA:

Pharmaceuticals and Medical Devices Agency

Polysorbate 80:

Polyoxyethylene (20) sorbitan monooleate

QC:

Quality control

RDRC:

Radioactive Drug Research Committee

RT:

Retention time

SPECT:

Single photon emission computed tomography

o-(Tol)3P:

Tri(o-tolyl)phosphine

Pd2(dba)3 :

Tris(dibenzylideneacetone)dipalladium(0)

UV:

Ultraviolet

References

  • Attwell D, Iadecola C. The neural basis of functional brain imaging signals. Trends Neurosci. 2002;25:621–5.

    Article  CAS  PubMed  Google Scholar 

  • Blau M. 1975. Letter: Radiation dosimetry of 131-I-19-iodocholesterol: The pitfalls of using tissue concentration data. J Nucl Med. 1975;16: 247-9.

  • Burns CM, Chen K, Kaszniak AW, Lee W, Alexander GE, Bandy D, et al. Higher serum glucose levels are associated with cerebral hypometabolism in Alzheimer regions. Neurology. 2013;80:1557–64.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  • Cowie CC, Rust KF, Byrd-Holt DD, Gregg EW, Ford ES, Geiss LS, et al. Prevalence of diabetes and high risk for diabetes using A1C criteria in the U.S. population in 1988–2006. Diabetes Care. 2010;33:562–8.

    Article  PubMed  PubMed Central  Google Scholar 

  • Doi H, Ban I, Nonoyama A, Sumi K, Kuang C, Hosoya T, et al. Palladium(0)-mediated rapid methylation and fluoromethylation on carbon frameworks by reacting methyl and fluoromethyl iodide with aryl and alkenyl boronic acid esters: useful for the synthesis of [11C]CH3--C- and [18F]FCH2--C-Containing PET tracers (PET = positron emission tomography). Chemistry. 2009;15:4165–71.

    Article  CAS  PubMed  Google Scholar 

  • FDA. US Food and Drug Administration. Radioactive Drug Research Committee. Human research without an investigational new drug application. 2010; FDA-2009-D-0125. Available from: Accessed Aug 2010.

  • ICRP. Radiological Protection in Biomedical Research. A report of Committee 3 adopted by the International Commission on Radiological Protection. Ann ICRP. 1991;22:1–v28.

    Article  Google Scholar 

  • ICRP. The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007;37:1–332.

    Google Scholar 

  • Ishibashi K, Onishi A, Fujiwara Y, Ishiwata K, Ishii K. Relationship between Alzheimer disease-like pattern of 18F-FDG and fasting plasma glucose levels in cognitively normal volunteers. J Nucl Med. 2015;56:229–33.

    Article  PubMed  Google Scholar 

  • Ishii K. Clinical application of positron emission tomography for diagnosis of dementia. Ann Nucl Med. 2002;16:515–25.

    Article  PubMed  Google Scholar 

  • Ishii K, Kanda T, Uemura T, Miyamoto N, Yoshikawa T, Shimada K, et al. Computer-assisted diagnostic system for neurodegenerative dementia using brain SPECT and 3D-SSP. Eur J Nucl Med Mol Imaging. 2009;36:831–40.

    Article  CAS  PubMed  Google Scholar 

  • Koziorowski J, Behe M, Decristoforo C, Ballinger J, Elsinga P, Ferrari V, et al. Position paper on requirements for toxicological studies in the specific case of radiopharmaceuticals. EJNMMI Radiopharm Chem. 2017;1:1.

    Article  CAS  PubMed  Google Scholar 

  • Matsuda H, Mizumura S, Nagao T, Ota T, Iizuka T, Nemoto K, et al. Automated discrimination between very early Alzheimer disease and controls using an easy Z-score imaging system for multicenter brain perfusion single-photon emission tomography. AJNR Am J Neuroradiol. 2007;28:731–6.

    CAS  PubMed  PubMed Central  Google Scholar 

  • Minoshima S. Imaging Alzheimer’s disease: clinical applications. Neuroimaging Clin N Am. 2003;13:769–80.

    Article  PubMed  Google Scholar 

  • Minoshima S, Koeppe RA, Frey KA, Ishihara M, Kuhl DE. Stereotactic PET atlas of the human brain: aid for visual interpretation of functional brain images. J Nucl Med. 1994;35:949–54.

    CAS  PubMed  Google Scholar 

  • Minoshima S, Cross D, Thientunyakit T, Foster NL, Drzezga A. 18F-FDG PET imaging in neurodegenerative dementing disorders: insights into subtype classification, emerging disease categories, and mixed dementia with copathologies. J Nucl Med. 2022;63:s2–12.

    Article  Google Scholar 

  • PMDA. Pharmaceuticals and Medical Devices Agency. ICH-Q3D (R2). Guideline for Elemental Impurities. Q3D(R2). 2022; Yakushoyaku-shin No. 0120-1. https://www.pmda.go.jp/files/000250228.pdf. Accessed 20 Jan 2023.

  • PMDA. Pharmaceuticals and Medical Devices Agency. The Japanese Pharmacopoeia 18th Edition. 2021; Notification No. 220. https://www.mhlw.go.jp/content/11120000/000945683.pdf. Accessed 7 Jun 2021.

  • PMDA. Pharmaceuticals and Medical Devices Agency. Revisions of the Guidelines for Single and Repeated Dose Toxicity Studies. 1993; Notification No. 88. https://www.pmda.go.jp/files/000156723.pdf. Accessed 10 Aug 1993.

  • PMDA. Pharmaceuticals and Medical Devices Agency. ICH-S2 (R1). Guidance on Genotoxicity Testing and Data Interpretation for Pharmaceuticals Intended for Human Use. 2012; Yakushoku-shinsa No. 0920-1. https://www.pmda.go.jp/files/000155984.pdf. Accessed 20 Sep 2012.

  • Reagan-Shaw S, Nihal M, Ahmad N. Dose translation from animal to human studies revisited. FASEB J. 2008;22:659–61.

    Article  CAS  PubMed  Google Scholar 

  • Sakata M, Ishibashi K, Imai M, Wagatsuma K, Ishii K, Zhou X, et al. Initial evaluation of an adenosine A2A receptor ligand, 11C-preladenant, in healthy human subjects. J Nucl Med. 2017;58:1464–70.

    Article  CAS  PubMed  Google Scholar 

  • Shimada H, Ishii K, Makizako H, Ishiwata K, Oda K, Suzukawa M. Effects of exercise on brain activity during walking in older adults: a randomized controlled trial. J Neuroeng Rehabil. 2017;14:50.

    Article  PubMed  PubMed Central  Google Scholar 

  • Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.

    PubMed  Google Scholar 

  • Tang BN, Minoshima S, George J, Robert A, Swine C, Laloux P, et al. Diagnosis of suspected Alzheimer’s disease is improved by automated analysis of regional cerebral blood flow. Eur J Nucl Med Mol Imaging. 2004;31:1487–94.

    Article  PubMed  Google Scholar 

  • Toyohara J, Sakata M, Wu J, Ishikawa M, Oda K, Ishii K, et al. Preclinical and the first clinical studies on [11C]CHIBA-1001 for mapping alpha7 nicotinic receptors by positron emission tomography. Ann Nucl Med. 2009;23:301–9.

    Article  CAS  PubMed  Google Scholar 

  • Toyohara J, Nariai T, Sakata M, Oda K, Ishii K, Kawabe T, et al. Whole-body distribution and brain tumor imaging with 11C-4DST: a pilot study. J Nucl Med. 2011;52:1322–8.

    Article  PubMed  Google Scholar 

  • Toyohara J, Sakata M, Fujinaga M, Yamasaki T, Oda K, Ishii K, et al. Preclinical and the first clinical studies on [11C]ITMM for mapping metabotropic glutamate receptor subtype 1 by positron emission tomography. Nucl Med Biol. 2013;40:214–20.

    Article  CAS  PubMed  Google Scholar 

  • Toyohara J, Sakata M, Hatano K, Yanai S, Endo S, Ishibashi K, et al. Preclinical and first-in-man studies of [11C]CB184 for imaging the 18-kDa translocator protein by positron emission tomography. Ann Nucl Med. 2016;30:534–43.

    Article  CAS  PubMed  Google Scholar 

  • Toyohara J, Harada N, Kakiuchi T, Ohba H, Kanazawa M, Tago T, et al. Synthesis and evaluation of N-isopropyl-p-[11C]methylamphetamine as a novel cerebral blood flow tracer for positron emission tomography. EJNMMI Res. 2020a;10:115.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  • Toyohara J, Sakata M, Tago T, Colabufo NA, Luurtsema G. Automated synthesis, preclinical toxicity, and radiation dosimetry of [18F]MC225 for clinical use: a tracer for measuring P-glycoprotein function at the blood-brain barrier. EJNMMI Res. 2020b;10:84.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  • Toyohara J, Brust P, Jia H, Sakata M, Ishiwata K. PET imaging of sigma1 receptors. In: Dierckx RA, Otte A, de Vries EF, van Warrde A, Lammertsma AA, editors. PET and SPECT of Neurobiological systems. Springer Cham.; 2021. pp. 943–71.

  • Villringer A, Dirnagl U. Coupling of brain activity and cerebral blood flow: basis of functional neuroimaging. Cerebrovasc Brain Metab Rev. 1995;7:240–76.

    CAS  PubMed  Google Scholar 

  • Wada-Isoe K, Uemura Y, Nakashita S, Yamawaki M, Tanaka K, Yamamoto M, et al. Prevalence of dementia and mild cognitive impairment in the rural island town of Ama-cho, Japan. Dement Geriatr Cogn Dis Extra. 2012;2:190–9.

    Article  PubMed  PubMed Central  Google Scholar 

  • Wienhard K. Measurement of glucose consumption using [18F]fluorodeoxyglucose. Methods. 2002;27:218–25.

    Article  CAS  PubMed  Google Scholar 

  • Zanotti-Fregonara P, Lammertsma AA, Innis RB. 11C dosimetry scans should be abandoned. J Nucl Med. 2021;62:158–9.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Mr. Kosuke Nishino and Mr. Masanari Sakai (SHI Accelerator Service, Tokyo, Japan) for technical support with cyclotron operation and radiosynthesis.

Funding

This work is partly supported by Grants-in Aid for Scientific Research (C) (Nos. 21K07663 and 24K10776) from the Japanese Society for the Promotion of Science.

Author information

Authors and Affiliations

Authors

Contributions

JT designed the study. JT and TT performed and analysed radiochemical and biological studies. MS analysed the biological studies and performed dosimetry analysis. JT wrote the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Jun Toyohara.

Ethics declarations

Ethics approval and consent to participate

All applicable institutional and/or national guidelines for the care and use of animals were followed, and the study protocol was approved by the institutional Research Ethics Board of Tokyo Metropolitan Institute for Geriatrics and Gerontology, and Nihon Bioresearch.

Consent for publication

Not applicable.

Competing interests

JT is an associate editor of EJNMMI Radiopharmacy and Chemistry. All other authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary Material 1

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Toyohara, J., Tago, T. & Sakata, M. Process validation and preclinical development of a new PET cerebral blood flow tracer [11C]MMP for initial clinical trials. EJNMMI radiopharm. chem. 9, 53 (2024). https://doi.org/10.1186/s41181-024-00285-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s41181-024-00285-9