Skip to main content

Table 3 Comparison of the number of patient syringes derived after preparation using both radiolabelling methods

From: Automated radiolabelling of [68Ga]Ga-PSMA-11 (gallium (68Ga)-gozetotide) using the Locametz® kit and two generators

Type of scanner

Number of patient syringes derived

SmPC preparation*

Number of patient syringes derived

Current method*

1 conventional PET/CT

2

3

2 conventional PET/CT in parallel

3

5

1 long axial field of view (LAFOV) PET/CT

7

10

  1. *Calculations were based on a required activity of [68Ga]Ga-PSMA-11 of 2 MBq/kg (average weight is 80 kg) when using conventional PET/CT and 50 MBq when using LAFOV PET/CT (EMA 2023). Time of positioning and scanning of a patient was assumed to be 45 min for conventional PET/CT and 15 min for LAFOV PET/CT