From: Automated, cassette-based isolation and formulation of high-purity [61Cu]CuCl2 from solid Ni targets
N | Target prepared from recycled Ni | Irradiation time | Current (μA) | Purpose |
---|---|---|---|---|
3 | No | 10–25 min | 10–20 | Optimization |
1 | No | 3.3 h | 30 | Scaled up demonstration |
3 | Yes, once | 30 min | 30 | Recycling evaluation |
2 | Yes, twice | 30 min | 30 | Recycling evaluation |
1 | Yes, manya | 60 min | 20 | Enriched material evaluation |