Table 4 FWHM determined for phantom hole-diameters of 1.3 mm for 44Sc and 43Sc in three different sections of the PET scan

From: Production and separation of 43Sc for radiopharmaceutical purposes

Radionuclide

Radionuclidic purity [%]

+ average [keV]

FWHM [mm]

44Sc

>99 (<1% 44mSc)

632

2.12 ± 0.04

43Sc from 43Ca

66.2 (33.3% 44Sc)

476

2.04 ± 0.06

43Sc from 46Ti

98.2 (1.5% 44Sc)

476

1.87 ± 0.14