Skip to main content

Table 1 Overview of suppliers of tests Lu177-precursors; * = ITM, ** = EZAG, *** = Monrol

From: Evaluation of the 177mLu-concentration in in-house produced 177Lu-radiopharmaceuticals and commercially available Lutathera®

Probe number

Supplier

Lu177m-impurity on certificate of analysis (%)

Production route

Activity of Lu177m [Bq/g] d.c

Activity of Lu177m [ppm] d.c

Activity of Lu177m [%] d.c

Measurement error [%]

0

1

2

3

4

5

6

7

1–97

EndolucinBeta®*

 < 0.01

n.c.a

381 ± 511a

0.00037 ± 0.00053a

0.0000037 ± 0.0000053a

 ≤ 4.7

98

177Lu Lutetiumchloride in aqueous solution **

 < 0.007

n.c.a

9521

0.00453

0.0000453

 ≤ 3.9

99

Lutetium chloride (Lu-177) radiopharmaceutical precursor solution nca ***

not detected

n.c.a

39

0.00002

0.0000002

 ≤ 3.7

100

LuMark®

0.00786

c.a

706,594

0.82479

0.008248

 ≤ 3.0

101–138

Lutathera® (n = 38, n = 25 for column 4)

 < 0.015

c.a

29,512 ± 

6491a

0.96 ± 0.17a

0.0096 ± 

0.0017a

 ≤ 2.6

  1. aStandard Deviation