Skip to main content

Table 2 18F-elution varying SPE cartridges, cartridge preconditioning, and the amount of Cu(OTf)2 or Cu(OTf)2(py)4

From: Fast and efficient copper-mediated 18F-fluorination of arylstannanes, aryl boronic acids, and aryl boronic esters without azeotropic drying

Entry (n = 3)

Cartridge

Cartridge pre-conditioning

Elution agent

Amount of the elution agent [μmol]

[18F]Fluoride recovery ± SD [%]

EEa ± SD [%]

1

QMA 130 mg

0.5 M LiOTf, H2O

Cu(OTf)2(py)4

24

47.1 ± 9.7

52.1 ± 11.3

2

QMA 130 mg

0.5 M LiOTf, H2O

Cu(OTf)2(py)4

48

52.5 ± 5.0

58.5 ± 7.5

3

QMA 130 mg

0.5 M LiOTf, H2O

Cu(OTf)2(py)4

96

64.3 ± 10.1

68.1 ± 10.0

4

QMA 130 mg

0.5 M LiOTf, H2O

Cu(OTf)2

24

48.6 ± 0.6

53.4 ± 1.3

5

QMA 130 mg

0.5 M LiOTf, H 2 O

Cu(OTf) 2

48

61.8 ± 9.1

69.2 ± 9.5

6

QMA 130 mg

0.5 M LiOTf, H2O

Cu(OTf)2

96

65.8 ± 7.9

70.7 ± 7.1

7

PS-HCO 3 45 mg

H 2 O

Cu(OTf) 2 (py) 4

12

24.2 ± 6.8

26.6 ± 7.3

8

PS-HCO3 45 mg

H2O

Cu(OTf)2(py)4

24

31.6 ± 9.1

35.3 ± 10.6

9

PS-HCO3 45 mg

H2O

Cu(OTf)2(py)4

48

57.3 ± 4.9

63.5 ± 5.9

10

PS-HCO3 45 mg

H2O

Cu(OTf)2

12

31.9 ± 18.8

35.6 ± 20.4

11

PS-HCO3 45 mg

H2O

Cu(OTf)2

24

41.1 ± 7.5

49.1 ± 8.6

12

PS-HCO3 45 mg

H2O

Cu(OTf)2

48

58.7 ± 9.0

64.5 ± 8.9

13

QMA 10 mg

0.5 M LiOTf, H2O

Cu(OTf)2(py)4

12

27.5 ± 8.3

31.4 ± 11.4

14

QMA 10 mg

0.5 M LiOTf, H2O

Cu(OTf)2(py)4

24

34.4 ± 8.8

40.5 ± 14.8

15

QMA 10 mg

0.5 M LiOTf, H2O

Cu(OTf)2(py)4

48

46.1 ± 9.9

52.9 ± 15.9

16

QMA 10 mg

0.5 M LiOTf, H2O

Cu(OTf)2

12

32.6 ± 13.4

38.8 ± 17.7

17

QMA 10 mg

0.5 M LiOTf, H2O

Cu(OTf)2

24

42.7 ± 6.3

50.4 ± 8.8

18

QMA 10 mg

0.5 M LiOTf, H2O

Cu(OTf)2

48

55.3 ± 3.6

62.8 ± 4.8

19

QMA carb 46 mg

H2O

Cu(OTf)2(py)4

48

38.7 ± 2.3

40.5 ± 3.1

20

QMA carb 46 mg

H2O

Cu(OTf)2

48

29.8 ± 5.8

32.1 ± 6.7

21

QMA carb 46 mg

0.5 M LiOTf, H2O

Cu(OTf)2(py)4

48

33.2 ± 5.4

35.1 ± 6.3

22

QMA carb 46 mg

0.5 M LiOTf, H2O

Cu(OTf)2

48

29.4 ± 11.3

31.4 ± 13.2

  1. aEE elution efficiency. Entries with the lowest and the highest elution efficiencies are highlighted